Study and set the parameters of industrial sensors and actuators
Calibrate and compare the technologies
GENERAL SPECIFICATIONS
- Water storage C0 :
Feed tank : about 50 L.
SS centrifugal pump : about 2 m3/h
By-pass ciruitry. - Tank :
Clear plastic tank, diameter 200 mm and height about 500 mm.
Feed pipe plunging into the tank.
Consumption pipe returning to feed tank.
On-Off electropneumatic valve. - Feed circuitry:
PVC pipes.
Analogue control device : valve or pump (see option 01 or 02).
Instrumentation
- Level detector.
- Electrovalves.
- Pressure transmitter.
- Flowrate transmitter.
Dim : 150 x 60 x 160 cm.
Télécharger la fiche
Control level
Unit designed for training technicians to adjust and/or maintain industrial control systems.
Depending on the options chosen, the test rig can be used for complete and varied studies of a PLC or a controller using either ON/OFF inputs (L1, L2)
or analogue inputs (LT1, FT1) and acting on either ON/OFF valves or analogue actuators (VR1, variable speed drive)
Study a simple
- Level control loop
- Flow control loop
- Level / flow rate cascade loop
Choose the actuator used for control
Control valve or variable speed drive on pump (see options)
Study an On/Off level control system
using solenoid valves (feed and evacuation)