Study, configuration and calibration of industrial sensors and installed actuators

Control without chemical products


GENERAL SPECIFICATIONS


  • 30 L, PE, tank with draining valve.
  • Feeding peristaltic pump, variable flow, manual control.
  • 10 L, tank in polypropylene with draining valve.
  • Control peristaltic pump, variable flow 4-20 Ma.
  • 20 L tank, in polypropylene with draining valve.
  • Glass plug flow reactor, with overflow outlet, drain valve and tracer injection.
  • Conductivity transmitter.

Instrumentation

  • Conduct meter probe.
  • Temperature probes Pt100Ω.
  • Flowmeter.
  • Configurable electronic PID control.
  • The 4-20mA signals available on wiring terminals Ø 4mm.

 

Dim (framework with casters) : 80 x 60 x 160 cm – 50 kg
Aluminum profile framework 30 x 30mm

 

Télécharger la fiche

Study of a physical value: conductivity

Study and setting a loop conductivity, by share on a peristaltic pump

 

Method with real pure delay