<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archives des Fluidization - Pignat.com</title>
	<atom:link href="https://pignat.com/en/product-category/educational-engineering/fluids-dynamics/fluidization-dynamic-fluids/feed/" rel="self" type="application/rss+xml" />
	<link>https://pignat.com/en/product-category/educational-engineering/fluids-dynamics/fluidization-dynamic-fluids/</link>
	<description></description>
	<lastBuildDate>Mon, 15 Mar 2021 09:46:55 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.1</generator>

<image>
	<url>https://pignat.com/wp-content/uploads/2019/01/cropped-Favicon-1-32x32.png</url>
	<title>Archives des Fluidization - Pignat.com</title>
	<link>https://pignat.com/en/product-category/educational-engineering/fluids-dynamics/fluidization-dynamic-fluids/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Solid-liquid fluidisation</title>
		<link>https://pignat.com/en/product/solid-liquid-fluidisation/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Tue, 16 Apr 2019 11:47:53 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=19573</guid>

					<description><![CDATA[<h3>Study the fluidisation with water of a bed of glass beads</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Polyethylene tank with removable lid and draining valve.</li>
<li>Stainless steel centrifugal pump.</li>
<li>PVC column, length 1 m, packed with glass beads, SS support grid, quick dismantling, two pressure sets.</li>
<li>Bed support by SS grid.</li>
<li>Weir enabling water flowing outlet towards the tank 1, retention grid.</li>
<li>Piezometric tube with stainless steel 1 m graduated ruler, a hand pump for the pressure setting, draining valve and quick fitting connections.</li>
<li>PVC column, length 1 m, packed with glass beads, SS support grid, quick dismantling, two pressure sets.</li>
</ul>
<p>&#160;</p>
<p><strong>Instruments</strong></p>
<ul>
<li>Flowmeters</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 110 x 80 x 180 cm - 150 kg</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/solid-liquid-fluidisation/">Solid-liquid fluidisation</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Study fluidisation</h3>
<p>Analyse pressure drops as a function of water flow rate</p>
<p>Determine the minimum fluidisation speed:</p>
<p style="padding-left: 60px;">experimentall</p>
<p style="padding-left: 60px;">from empirical equations</p>
<p>Study the expansion of the bed</p>
<p>&nbsp;</p>
<h3>Study the influence of parameters on fluidisation</h3>
<p>Column diameter</p>
<p>Glass bead diameter and density</p>
<p>Fluid flow rate</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/solid-liquid-fluidisation/">Solid-liquid fluidisation</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydrodinamic column</title>
		<link>https://pignat.com/en/product/hydrodinamic-column/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 07 Mar 2019 16:04:23 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18281</guid>

					<description><![CDATA[<h3>Hydrodynamic study of the three columns</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Polyethylene tank with removable lid and draining valve.</li>
<li>Submerged pump, low level detector, isolating valve.</li>
<li>Bubble tray column, isolating valve.</li>
<li>Glass column, packing with glass Raschig rings, isolating valve.</li>
<li>Glass column packing with Multiknit, isolating valve.</li>
<li>Fan, by-pass valve. Pressure measurements.</li>
</ul>
<p><b>Instrumentation</b></p>
<ul>
<li>Air float rotameter.</li>
<li>Water float rotameter.</li>
<li>U piping.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 200 x 75 x 240 cm - 235 kg<br />
SS tubular framework 40 x 40mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/hydrodinamic-column/">Hydrodinamic column</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Comparative study of the three columns</h3>
<p>Bubble tray column</p>
<p>Column packing with glass Raschig rings</p>
<p>Column packing with Multiknit</p>
<p><b> </b></p>
<h3>Study the hydrodynamics of three columns</h3>
<p>Determine conditions of operation and overflow conditions</p>
<p>Determine the pressure drop</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/hydrodinamic-column/">Hydrodinamic column</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gas solid fluidization</title>
		<link>https://pignat.com/en/product/gas-solid-fluidization/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 07 Mar 2019 15:50:32 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18283</guid>

					<description><![CDATA[<h3>Study air fluidization of solid particles</h3>
<blockquote><p>Implement pneumatic transport of solids</p></blockquote>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Air feeding circuitry with filter, pressure reducing valve.</li>
<li>Air flow rate measurement with float rotameter.</li>
<li>Fluidization chamber in glass, with bronze retention grid and solid particles bed.</li>
<li>Glass cyclone.</li>
<li>Filter to collect light particles (filtering capacity : 50μm). Solid particles delivered with the unit : recrystallized alumina.</li>
</ul>
<p><b>Instrumentation</b></p>
<ul>
<li>1 float rotameter.</li>
<li>Differential manometer with graduation.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 90 x 40 x 155 cm - 60 kg<br />
Aluminum profile frame</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/gas-solid-fluidization/">Gas solid fluidization</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Study air fluidization of solid particles</h3>
<p>Characterise the solid to be fluidized.</p>
<p>Apply experimental fluidization equations :</p>
<p>Define the ΔP graph for the fluidized bed as a function of air flow rate</p>
<p>Determine the minimum fluidization velocity</p>
<p>Influence of the height of the bed of particles</p>
<p>&nbsp;</p>
<h3>Understand the operation of a cyclone<b></b></h3>
</div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/gas-solid-fluidization/">Gas solid fluidization</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Gas solid fluidization drying</title>
		<link>https://pignat.com/en/product/gas-solid-fluidization-drying/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 07 Mar 2019 14:17:18 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18285</guid>

					<description><![CDATA[<h3>Study of the phenomena associated with the fluidization of solid particles in a stream of air</h3>
<blockquote><p>The kinetics of drying solid</p></blockquote>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Air feeding circuit with filter, pressure reducing valve and manometers, isolating valve.</li>
<li>PVC column with silica gel to dry air.</li>
<li>Air heating device equipped with an heating resistance with safety thermostat 90 °C.</li>
<li>Glass fluidization chamber with bronze fritted and solid particles bed.</li>
<li>Glass cyclone.</li>
<li>Piezometric tube with rule.</li>
</ul>
<p><b>Instrumentation</b></p>
<ul>
<li>3 temperature probes Pt100Ω.</li>
<li>Flowmeter.</li>
<li>2 Manometers.</li>
<li>Metal dial thermometer.</li>
<li>Moisture transmitter.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 125 x 55 x 155 cm - 70 kg<br />
Aluminum profile frame</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/gas-solid-fluidization-drying/">Gas solid fluidization drying</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>The fluidization process</h3>
<p>The study of heat transfer in a fluidized bed is an additional part of the Gas Solid Fluidization unit.</p>
<p>This additional equipment allows the characterization of heat exchanges.</p>
<p>We can measure the value of heat-transfer coefficient for different configurations of the bed of particles: fixed bed, fluidized bed and only air.</p>
<p>From a network of curves, we will plot the evolution of heat-transfer coefficient as a function of the air flow rate for a constant temperature of the filament.</p>
<p>This equipment can also define the criteria for fluidizing the alumina powder by monitoring the air flow and the pressure drop of the bed.</p>
<p>&nbsp;</p>
<h3>Study of the air fluidization of solid particles</h3>
<p>Characterize the solid to be fluidized</p>
<p>Determine the minimum fluidization speed</p>
<p>&nbsp;</p>
<h3>Study of the drying of solid particles in a hot air stream</h3>
<p>Apply the wet air graph</p>
<p>Determine the kinetic graphs for linear phase and diffusion phase drying</p>
<p><b> </b></p>
<h3>Study of the thermal convection coefficient (option)</h3>
<p>Compare the thermal convection coefficient for various medium configurations: in air, in a bed</p>
<p>of fixed particles and in a bed of fluidized particles.</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/gas-solid-fluidization-drying/">Gas solid fluidization drying</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Combined fluidization</title>
		<link>https://pignat.com/en/product/combined-fluidization/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 07 Mar 2019 14:05:17 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18287</guid>

					<description><![CDATA[<h3>Liquid-Solid  and Gas-Solid fluidization study</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Compressed air feeding circuit: general isolating valve, pressure reducing valve isolating valve.</li>
<li>Gas-solid fluidization: glass column, evacuation jar, glass fritted support, two pressure ports, quick-closing clamp.</li>
<li>Differential manometer of liquid column, filling valve, draining valve and scale.</li>
<li>Water feeding circuit: general isolating valve, float flowmeter with setting valve.</li>
<li>Solid-liquid fluidization: glass column, evacuation jar, support: glass perforated plate, two pressure ports, quick-closing clamp, recovery filter at the outlet.</li>
</ul>
<p><b>Instrumentation</b></p>
<ul>
<li>Air flowmeter.</li>
<li>Water flowmeter.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 105 x 55 x 175 cm - 60 kg<br />
SS tubular framework 40 x 40mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/combined-fluidization/">Combined fluidization</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Theoretical and experimental study of fluidization</h3>
<p>Porosity and expansion of bed, bubbling</p>
<p>Theoretically determination of the minimum fluidization velocity: Kozeny-Carman and Ergun equation</p>
<p>Experimentally determine the minimum fluidization speed</p>
<p><b> </b></p>
<h3>Study the influence of parameters on fluidization</h3>
<p>&nbsp;</p>
<h4>Bed characteristics:</h4>
<p>Particle diameter and density</p>
<p>Bed porosity and height.</p>
<h4>Fluid characteristics:</h4>
<p>Fluid flow rate and nature</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/combined-fluidization/">Combined fluidization</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Solid liquid fluidization</title>
		<link>https://pignat.com/en/product/solid-liquid-fluidization/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 07 Mar 2019 13:55:37 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18289</guid>

					<description><![CDATA[<h3>Study the fluidization with water of a bed of glass beads</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>100 L tank with removable lid.</li>
<li>SS centrifugal pump.</li>
<li>Glass column, packed.</li>
<li>ND 60 glass column, packed.</li>
</ul>
<ul>
<li>Glass column.</li>
<li>Set of valves: column selection and draining.</li>
</ul>
<p><b>Instrumentation</b></p>
<ul>
<li>2 flowmeters.</li>
<li>Piezometric tube, a hand pump for the<br />
pressure setting, draining valve.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 160 x 90 x 190 cm - 150 kg<br />
SS tubular framework 40 x 40mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>&#160;</p>
<p>L’article <a href="https://pignat.com/en/product/solid-liquid-fluidization/">Solid liquid fluidization</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Fluidization study</h3>
<p>Determine experimentally the minimum fluidization speed</p>
<p>Study the expansion of the bed</p>
<p>Analyze pressure drops as a function of water flow rate</p>
<p>&nbsp;</p>
<h3>Study the influence of parameters on fluidization</h3>
<p>Column diameter</p>
<p>Glass bead diameter and density</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/solid-liquid-fluidization/">Solid liquid fluidization</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
