<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Products - Pignat.com</title>
	<atom:link href="https://pignat.com/en/produits/feed/" rel="self" type="application/rss+xml" />
	<link>https://pignat.com/en/produits/</link>
	<description></description>
	<lastBuildDate>Tue, 20 Jul 2021 13:30:18 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://pignat.com/wp-content/uploads/2019/01/cropped-Favicon-1-32x32.png</url>
	<title>Products - Pignat.com</title>
	<link>https://pignat.com/en/produits/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Supervised temperature control</title>
		<link>https://pignat.com/en/product/temperature-control-supervised/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Tue, 20 Jul 2021 13:31:47 +0000</pubDate>
				<guid isPermaLink="false">https://pignat.com/?post_type=product&#038;p=31332</guid>

					<description><![CDATA[<h3>Study and adjust a temperature control loop</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Heating collar.</li>
<li>Temperature transmitter</li>
<li>Power controller</li>
<li>Cooling fan</li>
<li>USB port for data adquisition</li>
<li>RJ45 port for remote supervision</li>
<li>Color touch screen</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 80 x 60 x 80cm - 50 kg<br />
Aluminum profile framework  30 x 30mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/temperature-control-supervised/">Supervised temperature control</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Study and set the parameters of a PID controller</h3>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h3>Use a technical industrial file</h3>
</div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/temperature-control-supervised/">Supervised temperature control</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Supervised water flow control</title>
		<link>https://pignat.com/en/product/supervised-water-flow-control/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Mon, 19 Jul 2021 14:05:26 +0000</pubDate>
				<guid isPermaLink="false">https://pignat.com/?post_type=product&#038;p=31320</guid>

					<description><![CDATA[<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Control valve</li>
<li>Flow measurement by electronique flowmeter</li>
<li>Stainless steel three-way manifold, for transmitter setting</li>
<li>Disturbance piping</li>
<li>Three ways valve for draining.</li>
</ul>
<p><b>Instrumentation</b></p>
<ul>
<li>Electronic differential pressure transmitter.</li>
<li>Float flowmeter</li>
<li>Color touch screen.</li>
<li>The 4-20mA signals available on wiring terminals Ø 4mm.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 80 x 60 x 80cm - 50 kg<br />
Aluminum profile framework</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/supervised-water-flow-control/">Supervised water flow control</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Study and adjust a flow control loop</h3>
<p>Industrial actuators and sensors setting and study</p>
<p>Use a PID controller</p>
<p>Open loop study</p>
<p>Closed loop study</p>
<p>Further to a disruption controller reaction study</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/supervised-water-flow-control/">Supervised water flow control</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pressure sensors supervised</title>
		<link>https://pignat.com/en/product/pressure-sensors-supervised/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Mon, 12 Jul 2021 13:52:27 +0000</pubDate>
				<guid isPermaLink="false">https://pignat.com/?post_type=product&#038;p=31300</guid>

					<description><![CDATA[<h3>Pressure sensors different technologies study and comparison</h3>
<blockquote><p>On this unit you can also study the pressure control loop</p></blockquote>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Compressed air feeding with pressure reducer.</li>
<li>Pressure reducer with isolating valve.</li>
<li>Stainless steel compression box.</li>
<li>Manual vacuum pump.</li>
<li>Isolating valve on each sensor.</li>
</ul>
<p><b>Instrumentation</b></p>
<ul>
<li>Differential pressure transmitter.</li>
<li>Relative pressure transmitter 4-20mA.</li>
<li>Absolute pressure transmitter 4-20mA.</li>
<li>Pressure gauge.</li>
<li>Reference absolute pressure transmitter 4-20mA.</li>
<li>The 4-20mA signals available on wiring terminals Ø 4mm.</li>
<li>Color touch screen 4" with controller view, access to parameters and curves</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 80 x 60 x 80cm - 50 kg<br />
Aluminum profile framework 30 x 30mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/pressure-sensors-supervised/">Pressure sensors supervised</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Understanding of various pressures measured</h3>
<p>Absolute pressure</p>
<p>Relative pressure</p>
<p>Differential pressure</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/pressure-sensors-supervised/">Pressure sensors supervised</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Anaerobic digestion 50L &#8211; 100L</title>
		<link>https://pignat.com/en/product/anaerobic-digestion/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Mon, 28 Oct 2019 15:36:10 +0000</pubDate>
				<guid isPermaLink="false">https://pignat.com/?post_type=product&#038;p=21426</guid>

					<description><![CDATA[<h3>Show the different stages of anaerobic digestion</h3>
<blockquote><p>Monitoring the process for several weeks</p></blockquote>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Glass vessel, SS lid.</li>
<li>Feeding tank, in PVC, removable lid.</li>
<li>Balance with SS tray.</li>
<li>Draw-off tank, in PVC, removable lid.</li>
<li>Storage tank  in PE.</li>
<li>peristaltic pumps.</li>
<li>Draw-of peristaltic pump fixed speed.</li>
<li>Circuit air.</li>
<li>Option: Ritter high accuracy drum-type gas meter.</li>
</ul>
<p>&#160;</p>
<p><strong>Instrumentation</strong></p>
<ul>
<li>Temperature probe.</li>
<li>pH transmitter.</li>
<li>Safety thermostat.</li>
<li>Transmitted weight.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 200 x 70 x 200cm - 300 kg<br />
SS tubular framework 40 x 40mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/anaerobic-digestion/">Anaerobic digestion 50L &#8211; 100L</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Anaerobic digestion</h3>
<p>Anaerobic digestion is a collection of processes by which microorganisms brak down biodegradable material in the absence of oxygen</p>
<h3></h3>
<h3>Residence time distribution</h3>
<p>&nbsp;</p>
<h3>Hydrodynamic study</h3>
<p>&nbsp;</p>
<h3>Influence of reactor level</h3>
<p>&nbsp;</p>
<h3>Production of gas: Methane et CO<sub>2</sub></h3>
<p>&nbsp;</p>
<h3>Influence of the parameters</h3>
<p>Flowrate, pH and temperature</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/anaerobic-digestion/">Anaerobic digestion 50L &#8211; 100L</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mini pilot 4 parameters control</title>
		<link>https://pignat.com/en/product/4-parameters-control/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Mon, 28 Oct 2019 13:41:19 +0000</pubDate>
				<guid isPermaLink="false">https://pignat.com/?post_type=product&#038;p=21416</guid>

					<description><![CDATA[<h3>Unit designed for training technicians to adjust and/or maintain industrial control systems multiparameters</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Main glass transparent graduated tank. Level detector.</li>
<li>Stirring system, variable speed, stirring speed display.</li>
<li>Stainless steel immerged electrical heater, power.</li>
<li>Secondary glass transparent tank. Level detector.</li>
</ul>
<p>&#160;</p>
<p><b style="color: var(--vamtam-primary-font-color);">Instrumentation</b></p>
<ul>
<li>Temperature probes Pt100Ω.</li>
<li>Float flowmeter.</li>
<li>Electromagnetic flowmeter transmitter.</li>
<li>Relative pressure transmitter.</li>
<li>Differential pressure transmitter.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 140 x 55 x 110cm - 150 kg<br />
SS tubular framework 40 x 40mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/4-parameters-control/">Mini pilot 4 parameters control</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>4 Variable process control trainer</h3>
<p>The unit is autonomous, composed of two tanks and two pumps for running in closed circuit.</p>
<p>It allows to study and set several control loop simple or in cascade.</p>
<p>It includes :</p>
<p>– Water flow rate control by action on a valve</p>
<p>– Water level control by action on a valve</p>
<p>– Discharge pressure control by action on the pump’s variator</p>
<p>– Water level control by action on the pump’s variator</p>
<p>– Bath temperature control by action on an electrical heater</p>
<p>– Flow / level cascade control by action on a valve</p>
<p>Two control loops can function on the same time.</p>
<p>&nbsp;</p>
<p>The components installed are industrial one allowing a technologic study with the help of the technical documents in the technical file.</p>
<p>A tactile screen display the measures, control parameters setting, the functioning mode auto/manu, the data recording on a USB stick.</p>
<p>&nbsp;</p>
<h3>Study and adjust a number of simple control and cascade loops</h3>
<p>Temperature control</p>
<p>Level control</p>
<p>Flow control</p>
<p>Pressure control</p>
<p>Large choice of actuators : electrical heater, control valve or pump with frequency variator</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h3></h3>
</div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/4-parameters-control/">Mini pilot 4 parameters control</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Continuous Reactors RTD/REACTION</title>
		<link>https://pignat.com/en/product/rtd-reaction-continuous-reactors/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Fri, 25 Oct 2019 14:22:50 +0000</pubDate>
				<guid isPermaLink="false">https://pignat.com/?post_type=product&#038;p=21406</guid>

					<description><![CDATA[<h3>Study and comparison of two continuous reactors from two different experiments</h3>
<h3></h3>
<blockquote><p> Monitor the dispersion (NaCl) in water for determination residence time</p>
<p>The saponification of ethyl acetate by soda</p></blockquote>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Two diaphragm pumps, variable flow rate.</li>
<li>Two glass vessels for constant feed by overflow.</li>
<li>Variable rate Stirrer, SS stirring shaft with SS four blades helix.</li>
<li>Glass reactor, with PTFE cover.</li>
<li>Glass piston reactor.</li>
</ul>
<p>&#160;</p>
<p><strong>Instrumentation</strong></p>
<ul>
<li>Flowmeters.</li>
<li>Conductivity probes.</li>
<li>Temperature probe Pt100Ω.</li>
</ul>
<p>&#160;</p>
<p>Dim : 124 x 70 x 235 cm - 100 kg<br />
SS tubular framework 40 x 40mm</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/rtd-reaction-continuous-reactors/">Continuous Reactors RTD/REACTION</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Comparison of two different reactors with the same volume</h3>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h3>Determine the chemical conversion rate by conductivity measurement</h3>
</div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/rtd-reaction-continuous-reactors/">Continuous Reactors RTD/REACTION</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Industrial heat exchanger</title>
		<link>https://pignat.com/en/product/industrial-heat-exchanger/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Fri, 25 Oct 2019 11:38:43 +0000</pubDate>
				<guid isPermaLink="false">https://pignat.com/?post_type=product&#038;p=31064</guid>

					<description><![CDATA[<h3>Heat exchanger, industrial conception</h3>
<p>&#160;</p>
<hr />
<p>General specifications</p>
<hr />
<ul>
<li>Glass/stainless steel exchanger ECH01</li>
<li>Feeding tank with removable lid, level detector, overflow, feeding water.</li>
<li>Cooling water circuit, centrifugal pump, pressure measurement.</li>
<li>Steam circuit.</li>
</ul>
<p>&#160;</p>
<p><strong>Instrumentation</strong></p>
<ul>
<li>Electromagnetic flowmeter</li>
<li>Manometers</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> (framework) : 300 x 116 x 180 cm - 600 kg<br />
Aluminium framework</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/industrial-heat-exchanger/">Industrial heat exchanger</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Industial heat exchanger</h3>
<p>The unit is designed for the study of heat transfers between cold water and steam in the multitubular heat exchanger, at counter-current flow</p>
<h3></h3>
<h3>Study the parameters affecting heat transfer</h3>
<p>&nbsp;</p>
<p>&nbsp;</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/industrial-heat-exchanger/">Industrial heat exchanger</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Study of a major step in the oil industry</title>
		<link>https://pignat.com/en/product/study-of-a-major-step-in-the-oil-industry/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 02 May 2019 14:36:10 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=20014</guid>

					<description><![CDATA[<h3>Study of a major step in the oil industry</h3>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p><strong>Dim</strong> : 135 x 65 x 170 cm - 100 kg<br />
SS tubular framework 40 x 40mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/study-of-a-major-step-in-the-oil-industry/">Study of a major step in the oil industry</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Water, oil, gas separation in extraction well outlet</h3>
<p><span class="Apple-tab-span"> Products continuous recycling</span></p>
<p><span class="Apple-tab-span">Transparent separator ND200 easily removable</span></p>
<p><span class="Apple-tab-span"> Inter-phase level setting study</span></p>
<p><span class="Apple-tab-span"> Hydraulic gaskets ilustration</span></p>
<p><span class="Apple-tab-span"> Continuous decantation visualisation </span></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/study-of-a-major-step-in-the-oil-industry/">Study of a major step in the oil industry</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Utility module for water for one unit</title>
		<link>https://pignat.com/en/product/utility-module-for-water-for-one-unit/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 02 May 2019 14:27:24 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=20006</guid>

					<description><![CDATA[<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>90, polyethylene storage tank with removable cover and drain valve.</li>
<li>Immersed centrifugal pump.</li>
<li>Electrical connection</li>
<li>Aluminium section frame.</li>
<li>Four casters (two with brakes).</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 800 x 600 x 800mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/utility-module-for-water-for-one-unit/">Utility module for water for one unit</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">The MUT/2000 unit has been designed to feed with water a pilot plant of the control and automation rangeand to work on a closed loop without water consumption.</p>
<p>The unit to study can also be placed on the utility module becoming then a mobile unit.</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/utility-module-for-water-for-one-unit/">Utility module for water for one unit</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Level control integrator</title>
		<link>https://pignat.com/en/product/level-control-integrator/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 02 May 2019 14:14:12 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=19999</guid>

					<description><![CDATA[<h3>Study simple level control and flow control loops</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<p>Storage water C0:</p>
<ul>
<li>50L feeding tank</li>
<li>Centrifugal pump</li>
</ul>
<p>&#160;</p>
<p>Tank C1</p>
<ul>
<li>Transparent tank, Ø200, h=500mm</li>
<li>Disturbing piping</li>
<li>Volumetric pump.</li>
<li>Tri way valve</li>
</ul>
<p>&#160;</p>
<p>Tank C2</p>
<ul>
<li>Transparent tank, Ø200, h=500mm</li>
<li>Disturbing piping</li>
</ul>
<p>&#160;</p>
<p>Feeding circuit</p>
<ul>
<li>Control  valve</li>
<li>Flowrate transmitter</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 150 x 60 x 200cm - 100 kg<br />
Aluminum profile framework</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/level-control-integrator/">Level control integrator</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Study a level / flow rate cascade loop</h3>
<p>&nbsp;</p>
<h3>Study a level control integrator loop (volumetric pump P2 for drawing off at a regular flow rate)</h3>
<p>&nbsp;</p>
<h3>Operate safety devices: high level sensors in tanks, low level sensors to protect pumps.</h3>
<p>&nbsp;</p>
<h3>Study and set the parameters of industrial sensors and actuators.</h3>
<p>Sensors using different technologies are installed: level by bubbling or</p>
<p>by pressure, flow rate by electromagnetic flowmeter, control by solenoid valve or pump.</p>
<p>&nbsp;</p>
<p>The sensor and actuator signals are available for wiring on 4 mm safety jack sockets.</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/level-control-integrator/">Level control integrator</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>