<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archives des Automatism - Pignat.com</title>
	<atom:link href="https://pignat.com/en/product-category/educational-engineering/instrumentation-control/automatism/feed/" rel="self" type="application/rss+xml" />
	<link>https://pignat.com/en/product-category/educational-engineering/instrumentation-control/automatism/</link>
	<description></description>
	<lastBuildDate>Mon, 21 Oct 2019 08:25:05 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://pignat.com/wp-content/uploads/2019/01/cropped-Favicon-1-32x32.png</url>
	<title>Archives des Automatism - Pignat.com</title>
	<link>https://pignat.com/en/product-category/educational-engineering/instrumentation-control/automatism/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Model of permutation of pumps</title>
		<link>https://pignat.com/en/product/model-of-permutation-of-pumps/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Thu, 25 Apr 2019 09:08:15 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=19861</guid>

					<description><![CDATA[<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li><strong>Feeding tank: </strong>50L, in PVC, with transparent face, syphon draning valve.</li>
<li><strong>1th feeding line</strong>: with submerged pump, filling electrovalve.</li>
<li><strong>2th feeding line</strong>: with submerged pump, filling electrovalve.</li>
<li><strong>3th feeding line</strong>: with submerged pump, filling electrovalve.</li>
<li><strong>Tank</strong>: 15L, in PVC &#38; PMMA, with safety overflow, PVC electrovalve.</li>
</ul>
<p>&#160;</p>
<p><strong>Instrumentation</strong></p>
<ul>
<li>Electrovalves.</li>
<li>Six level detectors.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 90 x 50 x 110 cm - 80 kg<br />
Aluminum profile framework</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/model-of-permutation-of-pumps/">Model of permutation of pumps</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Study of a simple automated process</h3>
<p>&nbsp;</p>
<h3>Study of the filling of a tank and drainage</h3>
<p>&nbsp;</p>
<h3>Study of a compact system that works in closed circuit</h3>
<p>&nbsp;</p>
<h3>Proposal of practical work in teams</h3>
<p><span class="Apple-tab-span"> </span>Management of pumps</p>
<p><span class="Apple-tab-span"> </span>Management of solenoid valves</p>
<p>TON-level management</p>
<p>Available at the stage for connecting signals</p>
<p><span class="Apple-tab-span"> </span>A PLC or control system</p>
<p>&nbsp;</p>
<p>Unit comes complete with a full technical document (teaching manual, diagrams of principle, nomenclature, electrical diagrams, technical documents of the materials used)</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/model-of-permutation-of-pumps/">Model of permutation of pumps</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automate model</title>
		<link>https://pignat.com/en/product/automate-model/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Mon, 11 Mar 2019 16:22:15 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18218</guid>

					<description><![CDATA[<h3>Simulation of automated manufacturing process</h3>
<blockquote><p> Management preparation mixture from other tanks</p></blockquote>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>70 L, PVC, tank with transparent front, balancing and drain valve with siphon valve.</li>
<li>Submerged pump.</li>
<li>Filling electro valves, Kv = 11 L/min.</li>
</ul>
<ul>
<li>Upper tank, 3,5 L, in PVC and PMMA, with, draining electro valve.</li>
</ul>
<ul>
<li>Lower tank: 8 L, in PVC and PMMA, with, draining electrovalve.</li>
</ul>
<ul>
<li>Stirring: motor with variable speed.</li>
</ul>
<ul>
<li>Quick connectors for dual shutter interconnection of the two subsystems.</li>
</ul>
<p><b>Instrumentation </b></p>
<ul>
<li>Differential pressure sensor.</li>
<li>6 float level sensor.</li>
<li>The 4-20mA signals available on wiring terminals Ø 4mm.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 2(80 x 50 x 160) cm - 100 kg<br />
Aluminum profile framework</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/automate-model/">Automate model</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Study of a controlled system</h3>
<p>With two controllers on the network</p>
<p>Can be decomposed into two subsystems</p>
<p><b> </b></p>
<h3>Implementation of practical work and Automation logic</h3>
<p>Management levels AON, analog levels, pumps</p>
<p>On / off stirring</p>
<p>Opening filling valves, drain valves</p>
<p>Signals available at the front for achievements / O tests</p>
<p>&nbsp;</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/automate-model/">Automate model</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automated pumping station</title>
		<link>https://pignat.com/en/product/automated-pumping-station/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Mon, 11 Mar 2019 16:06:31 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18220</guid>

					<description><![CDATA[<h3>Study of the structure of a program/programming</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Suction circuit: 70L PVC tank, with removable lid, Draining valve by suction.</li>
<li>Submersible pump with safety float.</li>
<li>Lift circuit: setting valve.</li>
<li>Storage buffer tank, transparent column.</li>
<li>Loading circuit: Centrifugal pump, setting valve.</li>
<li>Water tower, transparent column, with lid. Three detectors AON level low, middle and high.</li>
<li>All inputs and outputs are pre - wiring.</li>
</ul>
<p><b>Instrumentation </b></p>
<ul>
<li>2 level sensor low flow.</li>
<li>Light indicators.</li>
</ul>
<p>&#160;</p>
<p>! Unit delivered with or without automaton.</p>
<p>&#160;</p>
<p><strong>Dim</strong> : 125 x 60 x 180 cm - 120 kg<br />
Aluminum profile framework 45 x 45mm</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/automated-pumping-station/">Automated pumping station</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Simulate a municipal water distribution network</h3>
<p>Study of a water control distribution network</p>
<p>Management of contact AON of buttons, pumps of controls and indicators</p>
<p>Operation in automatic mode or manual mode</p></div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/automated-pumping-station/">Automated pumping station</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automated weigh-batching</title>
		<link>https://pignat.com/en/product/automated-weigh-batching/</link>
		
		<dc:creator><![CDATA[PIGNAT]]></dc:creator>
		<pubDate>Mon, 11 Mar 2019 15:59:50 +0000</pubDate>
				<guid isPermaLink="false">http://v2.pignat.com/?post_type=product&#038;p=18227</guid>

					<description><![CDATA[<h3>Use a PLC to control a weigh-batching process</h3>
<p>&#160;</p>
<hr />
<p>GENERAL SPECIFICATIONS</p>
<hr />
<ul>
<li>Feeding tank, 6 L, with two solenoid valves</li>
<li>2 Feeding tank, 6L, with solenoid valve.</li>
<li>Stirring: controllable speed engine.</li>
<li>3 L PVC tank.</li>
<li>Draining valve with inductive proximity-effect sensor.</li>
<li>Load cell, 5 daN maxi, measurement mode by a weighing device.</li>
<li>Weight indicator, four configurable thresholds.</li>
</ul>
<p>&#160;</p>
<p><strong>Dim</strong> : 80 x 60 x 120 cm - 60 kg<br />
Aluminum profile framework</p>
<p>&#160;</p>
<p>[print-me target="#page"]</p>
<p>L’article <a href="https://pignat.com/en/product/automated-weigh-batching/">Automated weigh-batching</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
<h3>Analyze an automatic control chain</h3>
<p>Sensors, actuators, PLC,</p>
<p>Program and study a PLC</p>
<p>&nbsp;</p>
<h3>Security Management</h3>
</div>
<p><!-- .vgblk-rw-wrapper --></p>
<p>L’article <a href="https://pignat.com/en/product/automated-weigh-batching/">Automated weigh-batching</a> est apparu en premier sur <a href="https://pignat.com/en">Pignat.com</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
